How to Size a Centrifugal Pump: Head, Flow and Motor Power

How to Size a Centrifugal Pump: Head, Flow and Motor Power
เผยแพร่เมื่อ: 2026-10-22 | หมวดหมู่: Guide

Short answer

Choosing a centrifugal pump is a three-number decision: flow (Q), head (H) and motor power (P). Get all three right and the pump runs at its design point. Get them wrong and you either overload the motor or pay for capacity you never use. This guide shows how to read a Keliang pump performance table, work through a real sizing example, and match each duty point to a model in our range.



The three numbers you need

  • Flow (Q) - how much water you need per hour, expressed in m³/h or L/min. Keliang tables list flow at a set of heads, so flow and head are always read together, never separately.
  • Head (H) - the pressure the pump must overcome, in metres: the static lift plus friction losses in pipe and fittings. H.max is the maximum head the model can develop, and S.Head is the suction head available at the inlet.
  • Motor power (P) - the result of flow and head, which is why every Keliang model lists power in kW and HP next to the performance data.


How to read a Keliang performance table

Our centrifugal pump tables follow one layout. The model sits in the first column, followed by Output Power in kW and HP, then Current, then H.max in metres, Q.max in L/min, then the suction size and S.Head in metres. Multi-stage models such as the 2HCP series publish a performance curve instead: a row of head values with the matching flow printed under each one.

  • H.max (m) - the highest head the model can produce, at zero flow.
  • Q.max (L/min) - the maximum flow, at the lowest head.
  • S.Head (m) - the suction lift the pump tolerates. If your tank sits below the pump, this is the number to check.

Between the H.max and Q.max limits the pump delivers a specific flow at a specific head. That pair is your design point, and it is where model selection happens.



Worked example: 75 L/min at 45 m

Assume the duty is 75 L/min (4.5 m³/h) at 45 m of total head. Reading the 2HCP curve:

  • 2HCP-160 (1.5 kW / 2 HP) delivers 75 L/min at 45 m - on the point.
  • 2HCP-180 (2.2 kW / 3 HP) delivers 75 L/min at 48 m - on the point, with a larger motor.
  • 2HCP-200 (3 kW / 4 HP) delivers 75 L/min at 56 m - more head than the duty requires.

The rule is simple: take the smallest motor that still covers the duty point. For this application that is the 2HCP-160 at 1.5 kW, which also leaves head in reserve for pipe wear and filter fouling. If the duty were 100 L/min at 40 m instead, the same three models would drop to 37 m, 41 m and 52 m at that flow, and the 2HCP-180 would be the starting point. Send us the duty and we will check it against the real system curve before you order.



Where each Keliang series fits

All figures below are taken from the model tables on our product pages and from the water pump e-catalog.

ModelPowerMax headMax flowS.HeadTypical duty
CNG900.2 kW (0.3 HP)60 m9 L/min9 mHigh head, very low flow
CP-1280.37 kW (0.5 HP)22 m95 L/min8 mHousehold and small commercial transfer
CN1300.37 kW (0.5 HP)20 m90 L/min8 mWater tank and light irrigation
YHM-1300.37 kW (0.5 HP)20 m80 L/min8 mClean water circulation
SCM220.37 kW (0.5 HP)21 m86 L/min8 mCooling and circulation loops
DK 1DK140.25 kW (0.33 HP)13 m72 L/min8 mCompact low-head transfer
DK 2.5DKM-202 kW (3 HP)20 m600 L/min8 mHigher flow at moderate head
2HCP-1601.5 kW (2 HP)61 m shut-off, 57 m at 25 L/min250 L/mincurveMulti-stage, high head
2HCP-2003 kW (4 HP)65 m shut-off, 61.5 m at 25 L/min250 L/mincurveMulti-stage, high head and flow


Which Keliang model to choose

  • Single stage up to 0.75 kW: CP-128, CN, CNG, YHM and SCM series, with max head from 20 m (CN130) to 90 m (CNG130) and max flow from 9 L/min (CNG90) to 120 L/min (CN146/P).
  • 0.25 kW to 2 kW: the DK series, from 1DK14 at 13 m and 72 L/min up to 2.5DKM-20 at 20 m and 600 L/min.
  • Multi-stage and high head: the 2HCP series, 1.5 kW to 3 kW, covering 0 to 250 L/min with head between 37 m and 65 m across the curve.
  • Full range with dimensions and performance curves: download the water pump e-catalog.


Five mistakes that cost buyers money

  1. Sizing on Q.max. That is the maximum flow at the lowest head. Your duty point sits somewhere on the curve, and paying for the Q.max point means over-sizing the motor.
  2. Ignoring S.Head. If the pump has to lift from a tank below its own level, the suction head decides whether it primes at all.
  3. Choosing power by rule of thumb. The horsepower-per-litre-per-minute rule ignores head, and it is the head that consumes the power.
  4. Forgetting the electrical side. Voltage, frequency and phase must match the motor you order - check the specification line on the product page.
  5. Ignoring the fluid. Every figure in our tables refers to clean water; dense liquids, solids and high temperatures change the duty.


Send us your duty point

Tell us the flow, the head, the fluid and the power supply, and we will return the model, the curve and the quotation. Keliang has manufactured pumps in Fuan, China since 1991.

Factory sales: +86 186 5058 3355 · Email: sales@motors-world.com · Download the water pump catalogue · Send an inquiry